Knauf Insulation GmbH A-9586 Fürnitz Austria |
The criteria is relevant and the product supports the fulfillment of the criterion. | |
The criterion is relevant, but it must be demonstrated on a case-by-case basis for the products supplied in the respective construction project. | |
The criteria is not relevant for the application. | |
if an application is displayed in green, all relevant criteria of this application are met. | |
If at least one of the relevant criteria for an application is not met, the application is displayed in red. |
Types of application according to ÖNORM B 6000 (WW-C2/C3): | WW-MW Wood-wool dual-layer insulating board, comprising MW-WD (mineral wool) with single-sided coating of mineral-bonded wood wool |
no. | type | layer | d cm |
1 | KI Tektalan A2-E31-035 /2 (Holzwolle-Platte) | 1,00 | |
2 | KI Tektalan A2-E31-035 /2 (Steinwolle-Platte) | 11,50 | |
building element | 12,50 |
thickness: | 12,5 cm | ||
Dimensions (description): | 100 x 60 cm |
λaqu.: | 0,036 | W/(m·K) | |
ρmit. mittlere Rohdichte: | 141 | kg/m³ | |
Surface weight: | 17,7 | kg/m² | |
c specific heat capacity: | 1030 | J/(kg·K) | |
μ Vapour diffusion resistance factor: | 2 |
Flammability class: | A2 | ||
Smoke emission: | s1 = No/minimal smoke emission | ||
Flaming droplets: | d0 = No falling / dripping |
Installation (description): | not specified |
A1-A3 Product stage EI disposal indicator |
Wert | Unit |
Core environmental impact indicators | ||
GWP-fossil Global warming potential - fossil | 1,38 | kg CO2 Äq./kg |
GWP-biogenic Global warming potential - biogenic | -0,168 | kg CO2 Äq./kg |
GWP-total Global warming potential - total | 1,21 | kg CO2 Äq./kg |
ODP Depletion potential of the stratospheric ozone layer | 5,71·10-8 | kg CFC-11 eq./kg |
AP Acidification potential | 0,00872 | kg SO2 Äq./kg |
EP Eutrophication potential | 0,00231 | kg PO43- eq./kg |
POCP Photochemical Ozone Creation Potential | 0,00367 | kg C2H4 eq./kg |
Indicators describing resource use | ||
PERE Primary energy renewable - energy resources | 0,719 | MJ/kg |
PERM Primary energy renewable - material | 1,49 | MJ/kg |
PERT Primary energy renewable - total | 2,21 | MJ/kg |
PENRE Primary energy non-renewable - energy resources | 16,5 | MJ/kg |
PENRM Primary energy non-renewable - material | 0,00 | MJ/kg |
PENRT Primary energy non-renewable - total | 16,5 | MJ/kg |
Halogen-organic compounds: | 0 | w% | Richtwert |
Country of origin of raw materials (text): | not specified |
CE marking: | yes | ||
CE Certificate of conformity: | Tektalan_A2_E31_035_2_CE.pdf (499 KB) issued by: FIW München | ||
CE Declaration of Performance: | Tektalan_A2_E31_035_2_LE.pdf (1,26 MB) issued on July 1, 2013 |
PDF (241 KB) issued on Nov 13, 2012 |
Safety data sheet: | not available |
A. Pümpel GmbH & Co. KG. A-6800 Feldkirch Austria | |
August Rädler GmbH A-6922 Wolfurt Austria | |
MBA - DÄMMSTOFFE GmbH A-6850 Dornbirn Austria | |
Tischler Rohstoff e.Gen. A-6845 Hohenems Austria | |
Tschabrun Hermann GmbH A-6830 Rankweil Austria |
Listed since: | Feb 26, 2015 | ||
baubook product index: | 1994 ez |
|