Voranstrich PC® EM
link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142724221&SW=16&lng=2

Manufacturer
Pittsburgh Corning Ges.m.b.H.
A-4020 Linz
Austria
 
Description
Product groups: Bitumen pre-coatings, primers
Materials used: lösungsmittelfreie Bitumenemulsion
Renewable raw materials: 0w%
Mineral raw materials: 0w%
Reference value: Bitumen coating
 
Criteria for certification, tendering and subsidies
List of Criteria 2020

The criteria is relevant and the product supports the fulfillment of the criterion.
 
Technical characteristics
Physical parameters
λ thermal conductivity:
0,23
W/(m·K)Richtwert
ρ density:
1050
kg/m³Richtwert
c specific heat capacity: not specifiedJ/(kg·K)
 
Physiochemical properties
pH value: 10
 
Serviceability
Resistant against: Water
 
Processing properties
Installation (description): not specified
Processing temperature, at least: 5°C
Consumption per procedure (l/m²): 0,3l/m²
Consumption per procedure (kg/m²): 0,3kg/m²
Number of procedures required: 1
Drying time: ranging from 3 up to 12hour(s)

Information for multi-component products
Component A: Bitumenemulsion
Mixing ratio: Als Voranstrich bei Verwendung von Heißbitumen als Kleber:
Material 1:3 Raumteile mit Wasser verdünnen (1 Raumteil PC® EM, 3 Raumteile Wasser).
Als Voranstrich bei Verwendung von Bitumen-Kaltkleber PC® 56 und PC® 58 :
Material 1:10 Raumteile mit Wasser verdünnen (1 Raumteil PC® EM, 10 Raumteile Wasser).
 
Life Cycle Assessment (LCA)
Background database Ecoinvent A1
A1-A3 Product stage
EI disposal indicator
reference Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil 1,07 kg CO2 Äq./kg
GWP-biogenic Global warming potential - biogenic 0,00 kg CO2 Äq./kg
GWP-total Global warming potential - total 1,07 kg CO2 Äq./kg
ODP Depletion potential of the stratospheric ozone layer 1,77·10-7 kg CFC-11 eq./kg
AP Acidification potential 0,00441 kg SO2 Äq./kg
EP Eutrophication potential 0,000513 kg PO43- eq./kg
POCP Photochemical Ozone Creation Potential 0,383 kg C2H4 eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources 0,121 MJ/kg
PERM Primary energy renewable - material 0,00 MJ/kg
PERT Primary energy renewable - total 0,121 MJ/kg
PENRE Primary energy non-renewable - energy resources 12,8 MJ/kg
PENRM Primary energy non-renewable - material 42,6 MJ/kg
PENRT Primary energy non-renewable - total 55,4 MJ/kg
Quelle: IBO benchmarks 2020, ab 17.2.2023
 
 
Ecological characteristics
Ingredients
SVHC (Substances of Very High Concern): Das verkaufsfertige Endprodukt enthält keinen besonders besorgniserregenden Stoff (SVHC) der Kandidatenliste mit mehr als 0,1 Gew.-% pro Einzelstoff.
VOC (g/l): 0g/l
VOC explanation:
Actual value
Halogen-organic compounds: 0w%
 
Service area
CE marking
CE marking: not specified
 
GHS hazard statement, warnings, hazard classes
Water pollution class:
1
 
GISCODE
Download
Technical data sheet:
issued on Feb 7, 2017
Safety data sheet:
issued on Oct 29, 2020
 
Retailer
A. Pümpel GmbH & Co. KG.
A-6800 Feldkirch
Austria
 
baubook declaration
Listed since: Dec 10, 2019
Amended: Sept 7, 2023
baubook product index: 9461 ad
 
baubook green procurement
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”
print page
share this page