ACTUAL MATRIX 9 Kunststoff-Fensterrahmen Uf 1,0
link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142731352&SW=16&lng=2

Manufacturer
ACTUAL Fenster Türen Sonnenschutz
A-4053 Haid / Ansfelden
Austria
 
Description
Product groups: Plastic frame
Reference value: Plastic frame <=71 block frame depth < 88
 
Criteria for certification, tendering and subsidies
List of Criteria 2020

The criteria is relevant and the product supports the fulfillment of the criterion.
The criteria is relevant and the product does not support the fulfillment of the criterion or there are no validation documents available.
 
Technical characteristics
Dimensions
Frame width:
oben/seitlich not specified
unten not specified
gemittelt 0,108
m
Glazing bar width:
0,03
mRichtwert
 
Physical parameters
UfHeat transmission coefficient of window frames:
oben/seitlich not specified
unten not specified
gemittelt 1
W/(m²·K)
 
Life Cycle Assessment (LCA)
Background database Ecoinvent A1
A1-A3 Product stage
EI disposal indicator
reference Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil 270 kg CO2 Äq./m²
GWP-biogenic Global warming potential - biogenic 0,00 kg CO2 Äq./m²
GWP-total Global warming potential - total 270 kg CO2 Äq./m²
ODP Depletion potential of the stratospheric ozone layer 1,41·10-5 kg CFC-11 eq./m²
AP Acidification potential 1,04 kg SO2 Äq./m²
EP Eutrophication potential 0,509 kg PO43- eq./m²
POCP Photochemical Ozone Creation Potential 0,178 kg C2H4 eq./m²
Indicators describing resource use
PERE Primary energy renewable - energy resources 258 MJ/m²
PERM Primary energy renewable - material 0,00 MJ/m²
PERT Primary energy renewable - total 258 MJ/m²
PENRE Primary energy non-renewable - energy resources 4.425 MJ/m²
PENRM Primary energy non-renewable - material 864 MJ/m²
PENRT Primary energy non-renewable - total 5.289 MJ/m²
Quelle: IBO benchmarks 2020, ab 17.2.2023
 
 
Ecological characteristics
Ingredients
Insulation materials free from climate-damaging substances:
Product does not contain any insulating materials
 
Service area
CE marking
CE marking: not specified
 
Download
Test certificate in accordance with ÖNORM EN ISO 10077:
  • available
    issued on Mar 21, 2017
    issued by: Frauenhofer-Institut für Bauphysik IBP
  • available
    issued on Nov 21, 2018
    issued by: Frauenhofer-Institut für Bauphysik IBP
 
baubook declaration
Listed since: Mar 21, 2019
baubook product index: 1925 cf
 
baubook green procurement
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”
print page
share this page