ALUKÖNIGSTAHL GmbH A-1150 Wien Austria |
Product groups: | Metal frame | ||
Product photos: | |||
Reference value: | Aluminium metal frame (with thermal separation) |
2. 2. 3. Ban of substances with greenhouse effects | |
2. 4. 1. Ban of PVC | |
2. 4. 2. Limits for organohalogen compounds |
The criteria is relevant and the product supports the fulfillment of the criterion. |
Frame width: |
| m | |||||||
Glazing bar width: | 0,03 | m | Richtwert |
UfHeat transmission coefficient of window frames: |
| W/(m²·K) |
A1-A3 Product stage EI disposal indicator |
Wert | Unit |
Core environmental impact indicators | ||
GWP-fossil Global warming potential - fossil | 463 | kg CO2 Äq./m² |
GWP-biogenic Global warming potential - biogenic | 0,00 | kg CO2 Äq./m² |
GWP-total Global warming potential - total | 463 | kg CO2 Äq./m² |
ODP Depletion potential of the stratospheric ozone layer | 2,20·10-5 | kg CFC-11 eq./m² |
AP Acidification potential | 2,54 | kg SO2 Äq./m² |
EP Eutrophication potential | 0,857 | kg PO43- eq./m² |
POCP Photochemical Ozone Creation Potential | 0,238 | kg C2H4 eq./m² |
Indicators describing resource use | ||
PERE Primary energy renewable - energy resources | 558 | MJ/m² |
PERM Primary energy renewable - material | 0,00 | MJ/m² |
PERT Primary energy renewable - total | 558 | MJ/m² |
PENRE Primary energy non-renewable - energy resources | 5.337 | MJ/m² |
PENRM Primary energy non-renewable - material | 477 | MJ/m² |
PENRT Primary energy non-renewable - total | 5.814 | MJ/m² |
Environmental Product Declaration (EPD) - ecoinvent A1: | Fenstersysteme Schüco AWS (975 KB) valid until June 26, 2025 |
Insulation materials free from climate-damaging substances: | The insulation material used does not contain any (H)PFCs or (H)CFCs with a GWP > 1 |
CE marking: | not specified |
Test certificate in accordance with ÖNORM EN ISO 10077: | available issued on Feb 3, 2011 issued by: ift Rosenheim |
Listed since: | Nov 19, 2020 | ||
Amended: | Mar 2, 2021 | ||
baubook product index: | 8786 am |
|