Spruce wood frame <= 74 block frame depth <91

link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142743604&SG=2142736021&SKg=2&SW=16&lng=2

Last changed:
baubook reference value: 16. 8. 2021
Building physics parameters: 16. 8. 2021
Ecological building parameters: 27. 1. 2022

Bauprodukte
Fenster und -komponenten
Fensterrahmen
Holzrahmen


Kennwerte
Building physics parameters
KennwertRichtw.EinheitQuelle
Wärmedurchgangskoef. (Uf)1,25W/m²K
Rahmenbreite0,12m
Sprossenbreite0,03m
Ecological building parameters: Background database Ecoinvent A1
EI disposal indicatorRichtw.Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil131kg CO2 Äq./m²
GWP-biogenic Global warming potential - biogenic-94,5kg CO2 Äq./m²
GWP-total Global warming potential - total36,7kg CO2 Äq./m²
ODP Depletion potential of the stratospheric ozone layer0,00000868kg CFC-11 eq./m²
AP Acidification potential0,614kg SO2 Äq./m²
EP Eutrophication potential0,341kg PO43- eq./m²
POCP Photochemical Ozone Creation Potential0,0732kg C2H4 eq./m²
Indicators describing resource use
PERE Primary energy renewable - energy resources84,2MJ/m²
PERM Primary energy renewable - material1092MJ/m²
PERT Primary energy renewable - total1177MJ/m²
PENRE Primary energy non-renewable - energy resources2197MJ/m²
PENRM Primary energy non-renewable - material86,2MJ/m²
PENRT Primary energy non-renewable - total2283MJ/m²
Beschreibung des Richtwerts

Korrektur am 16.08.2021: Langtitel richtig gestellt (">= 74" statt "<= 74")

 
Produkte mit diesem Richtwert
2 Produkte Hersteller
Böhler HOLZ-FENSTER boe_classic + (Rahmen)Böhler Fenster GmbH
Böhler HOLZ-FENSTER boe_design + (Rahmen)Böhler Fenster GmbH
baubook green procurement
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”