Armacell Austria GmbH A-9585 Gödersdorf Austria |
Product groups: | Insulation materials for distribution systems | ||
Materials used: | Hauptstoff ist Steinwolle, kaschiert mit Reinaluminiumfolie | ||
Reference value: | Aluminium vapour barrier |
2. 2. 3. Ban of substances with greenhouse effects | |
2. 4. 1. Ban of PVC | |
2. 4. 2. Limits for organohalogen compounds |
The criteria is relevant and the product supports the fulfillment of the criterion. |
Dimensions (description): | Dämmdicken von 20 bis 100mm Rohrdurchmesser von 12 bis 133mm für nicht brennbare Rohrsysteme und 16 bis 63mm für brennbare Rohrsysteme |
c specific heat capacity: | 900 | J/(kg·K) | Richtwert |
μ Vapour diffusion resistance factor: | 9999999 | Richtwert |
Installation (description): | not specified |
A1-A3 Product stage EI disposal indicator |
reference | Unit |
Core environmental impact indicators | ||
GWP-fossil Global warming potential - fossil | 33,5 | kg CO2 Äq./kg |
GWP-biogenic Global warming potential - biogenic | -0,0560 | kg CO2 Äq./kg |
GWP-total Global warming potential - total | 33,4 | kg CO2 Äq./kg |
ODP Depletion potential of the stratospheric ozone layer | 1,79·10-6 | kg CFC-11 eq./kg |
AP Acidification potential | 0,157 | kg SO2 Äq./kg |
EP Eutrophication potential | 0,0933 | kg PO43- eq./kg |
POCP Photochemical Ozone Creation Potential | 0,0109 | kg C2H4 eq./kg |
Indicators describing resource use | ||
PERE Primary energy renewable - energy resources | 57,9 | MJ/kg |
PERM Primary energy renewable - material | 0,00 | MJ/kg |
PERT Primary energy renewable - total | 57,9 | MJ/kg |
PENRE Primary energy non-renewable - energy resources | 552 | MJ/kg |
PENRM Primary energy non-renewable - material | 0,00 | MJ/kg |
PENRT Primary energy non-renewable - total | 552 | MJ/kg |
Insulation materials free from climate-damaging substances: | The insulation material used does not contain any (H)PFCs or (H)CFCs with a GWP > 1 |
CE marking: | yes | ||
CE Certificate of conformity: | issued by: MPA Nordrhein-Westfalen | ||
CE Declaration of Performance: | issued on Nov 12, 2021 |
Technical data sheet: | 200609_TDB_056FPA_FIRE_PROOF.pdf (198 KB) issued on June 9, 2020 | ||
European Technical Approval (ETA): | available valid until Dec 31, 2060 issued by: Österreichischen Institut für Bautechnik |
Listed since: | Feb 2, 2023 | ||
baubook product index: | 9340 bk |
|