Last changed: baubook reference value: 14. 3. 2013 Building physics parameters: 21. 3. 2013 Ecological building parameters: 19. 2. 2020 Bauprodukte Dämmstoffe Dämmstoffe aus nachwachsenden Rohstoffen • Zellulosefaser-Dämmstoffe
|
Kennwert | Richtw. | Einheit | Quelle |
ρ | 54 | ||
λr | |||
Defaultwert | 0,041 | ||
Möglicher Wert | 0,038 | ||
μ | |||
trocken | 2 | ||
feucht | 2 | ||
c | 1600 |
EI disposal indicator | Richtw. | Unit |
---|---|---|
Core environmental impact indicators | ||
GWP-fossil Global warming potential - fossil | 0,546 | kg CO2 Äq./kg |
GWP-biogenic Global warming potential - biogenic | -1,00 | kg CO2 Äq./kg |
GWP-total Global warming potential - total | -0,457 | kg CO2 Äq./kg |
ODP Depletion potential of the stratospheric ozone layer | 0,0000000433 | kg CFC-11 eq./kg |
AP Acidification potential | 0,00335 | kg SO2 Äq./kg |
EP Eutrophication potential | 0,00135 | kg PO43- eq./kg |
POCP Photochemical Ozone Creation Potential | 0,000279 | kg C2H4 eq./kg |
Indicators describing resource use | ||
PERE Primary energy renewable - energy resources | 1,07 | MJ/kg |
PERM Primary energy renewable - material | 10,4 | MJ/kg |
PERT Primary energy renewable - total | 11,5 | MJ/kg |
PENRE Primary energy non-renewable - energy resources | 6,87 | MJ/kg |
PENRM Primary energy non-renewable - material | 0 | MJ/kg |
PENRT Primary energy non-renewable - total | 6,87 | MJ/kg |
Produkte mit diesem Richtwert | ||||||
|
|