Aluminium bitumen sealing membrane

link to this page:
https://www.baubook.at/m/PHP/Info.php?SI=2142741380&SG=2142700440&SKg=2&SW=16&lng=2

Last changed:
baubook reference value: 14. 9. 2008
Building physics parameters: 15. 9. 2008
Ecological building parameters: 19. 2. 2020

Bauprodukte
Dichtungsbahnen, Dampfsperren, Folien & Vliese
Aluminium-Dampfsperrbahnen
Bitumenbahnen


Kennwerte
Building physics parameters
KennwertRichtw.Einheit
ρ  
Richtwert1.100kg/m³
obere Grenze1.100kg/m³
λ  
Richtwert0,230W/mK
μ  
Richtwert36000
c1260J/kgK
Ecological building parameters: Background database Ecoinvent A1
EI disposal indicatorRichtw.Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil1,63kg CO2 Äq./kg
GWP-biogenic Global warming potential - biogenic-0,024kg CO2 Äq./kg
GWP-total Global warming potential - total1,60kg CO2 Äq./kg
ODP Depletion potential of the stratospheric ozone layer0,000000336kg CFC-11 eq./kg
AP Acidification potential0,00869kg SO2 Äq./kg
EP Eutrophication potential0,00209kg PO43- eq./kg
POCP Photochemical Ozone Creation Potential0,00123kg C2H4 eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources2,48MJ/kg
PERM Primary energy renewable - material0MJ/kg
PERT Primary energy renewable - total2,48MJ/kg
PENRE Primary energy non-renewable - energy resources25,1MJ/kg
PENRM Primary energy non-renewable - material26,1MJ/kg
PENRT Primary energy non-renewable - total51,2MJ/kg
Produkte mit diesem Richtwert
3 Produkte Hersteller
Sarnavap 5000 E SASika Österreich GmbH
Villas Hydrostop Multi 4BMI Austria GmbH - Villas
Villas Hydrostop Multi 5BMI Austria GmbH - Villas
baubook green procurement
Harmonised “EcoBuildingCriteria” provided by “ÖkoKauf Wien” and “service package sustainable construction in Vorarlberg”