ISOLENA Schafwolle, Klemmfilz, 30 kg/m³
| Manufacturer | ISOLENA Naturfaservliese GmbH |
| Product group(s) | Sheep's wool insulation |
| Product images |
|
| Description of area of application | Thermal insulation: Internal wall, Partition wall insulation, Installation level, Partition wall lining, Room air renovation
Sound insulation: Ceiling insulation, suspended ceiling, Sound proof ceiling, Acoustic ceiling |
| Manufacturer's product description | Sheep's wool insulation ISOLENA Klemmfilz 30kg/m³ with biocide-free wool protection Ionic Protect® made from 100% pure sheep's wool without synthetic additives or supporting fibres. The insulating material is renewable, durable, reusable and fully recyclable. |
| Processing | Installation: Install insulation rolls tightly butted together from bottom to top. Sufficient and slip-proof fastening. Quick installation, ideally suited for working overhead. No dust mask and no protective clothing necessary. The rolls can be cut to length by tearing by hand or with the ISOLENA cutting device. How it works! https://www.isolena.com/en/know-how/sheepwool-insulation-installation-videos.html |
| Origin of the main ingredients | Europe |
| Details | Show detailed information from baubook |
| Eco-labels, quality seals, labels | natureplus natureplus |
| Platforms | Vorarlberg WBF klimaaktiv Kriterien Niederösterreich WBF ÖkoBauKriterien natureplus BNB/QNG-Produktinfo wohngsund |
| Product Index | 2002 ac |
| Dimensions | ||
|---|---|---|
| Format l x w | 9,000 mm x 600 mm 6,000 mm x 600 mm 4,000 mm x 600 mm |
|
| Thickness | 3, 4, 5, 6, 8 cm | |
| Dimensions (description) | Standard dimensions are available in width of 600mm and lengths of 4000-9000mm. Special dimensions upon request. | |
| Manufacturer warranty | The manufacturer offers a product assurance on the quality and functionality of the insulation products made from 100% sheep's wool. This guarantee covers the material durability and the insulation properties under normal conditions of use in accordance with the applicable technical regulations. Damage caused by improper use is excluded. | |
| Building physics values | ||
| 0.036 | W/(m·K) | |
| 1 | ||
| 1 | ||
| 1 | ||
| 30 | kg/m³ | |
| 30 | kg/m³ | |
| 30 | kg/m³ | |
| 1760 | J/(kg·K) | |
| Usability | ||
| Combustibility class | D | |
| Smoke development | s2 | |
| Flaming droplets | d0 | |
| CE marking | yes | |