XPS–G 30 > 180 mm (32 kg/m³)

Last changed:
baubook reference value: 13. 3. 2013
Building physics parameters: 2. 4. 2013
Ecological building parameters, IBO benchmarks 2012: 10. 9. 2014
Ecological building parameters, IBO benchmarks 2020: 8. 2. 2018
Ecological building parameters, ökobaudat: 6. 3. 2023

Bauprodukte
Dämmstoffe
Synthetische Dämmstoffe
XPS-Dämmplatten

range of application of the reference value
Bemessungswert der Wärmeleitfähigkeit auf Basis des Fraktil-Wertes (90 %-Fraktile) gemäß der jeweiligen Produktnorm für eine Ausgleichsfeuchte bei 23 °C und 80 % relative Luftfeuchte.
 
Kennwerte
Building physics parameters
KennwertRichtw.EinheitQuelle
ρ32kg/m³
λr   
Defaultwert0,042W/mK
Möglicher Wert0,038W/mK
μ   
trocken150
feucht150
c1450J/kgK
Ecological building parameters: Background database Ecoinvent A1
EI disposal indicatorIBO 2012IBO 2020Unit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil4,204,24kg CO2 Äq./kg
GWP-biogenic Global warming potential - biogenic00kg CO2 Äq./kg
GWP-total Global warming potential - total4,204,24kg CO2 Äq./kg
ODP Depletion potential of the stratospheric ozone layer0,00000006130,0000000613kg CFC-11 eq./kg
AP Acidification potential0,01550,0155kg SO2 Äq./kg
EP Eutrophication potential0,002570,00257kg PO43- eq./kg
POCP Photochemical Ozone Creation Potential0,006840,00816kg C2H4 eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources0,8790,879MJ/kg
PERM Primary energy renewable - material00MJ/kg
PERT Primary energy renewable - total0,8790,879MJ/kg
PENRE Primary energy non-renewable - energy resources53,653,6MJ/kg
PENRM Primary energy non-renewable - material4040MJ/kg
PENRT Primary energy non-renewable - total93,693,6MJ/kg
Ecological building parameters: Background database GaBi A1
EI disposal indicatorökobaudatUnit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil3,01kg CO2 Äq./kg
GWP-biogenic Global warming potential - biogenic0kg CO2 Äq./kg
GWP-total Global warming potential - total3,01kg CO2 Äq./kg
ODP Depletion potential of the stratospheric ozone layer0kg CFC-11 eq./kg
AP Acidification potential0,00409kg SO2 Äq./kg
EP Eutrophication potential0,000523kg PO43- eq./kg
POCP Photochemical Ozone Creation Potential0,00139kg C2H4 eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources5,58MJ/kg
PERM Primary energy renewable - material0MJ/kg
PERT Primary energy renewable - total5,58MJ/kg
PENRE Primary energy non-renewable - energy resources43,9MJ/kg
PENRM Primary energy non-renewable - material44,8MJ/kg
PENRT Primary energy non-renewable - total88,7MJ/kg
Core environmental impact indicators
ADPE Abiotic depletion potential for non fossil resources0,000000469kg Sb eq./kg
ADPF Abiotic depletion potential for fossil resources86,7MJ/kg
Indicators describing resource use
SM Use of secondary material0kg/kg
RSF Use of renewable secondary fuels0MJ/kg
NRSF Use of non renewable secondary fuels0MJ/kg
FW Use of net fresh water0,0139m³/kg
Environmental information describing waste categories
HWD Hazardous waste disposed0,0000000364kg/kg
NHWD Non hazardous waste dispose0,0203kg/kg
RWD Radioactive waste disposed0,000798kg/kg
Environmental information describing output flows
CRU Components for re-use0kg/kg
MFR Materials for recycling0kg/kg
MER Materials for energy recovery0kg/kg
EEE Exported electrical energy0MJ/kg
EET Exported thermal energy0MJ/kg
Ecological building parameters: Background database Gabi A2
EI disposal indicatorökobaudatUnit
Core environmental impact indicators
GWP-fossil Global warming potential - fossil fuels2,95kg CO2 eq./kg
GWP-biogenic Global warming potential - biogenic0,0181kg CO2 eq./kg
GWP-luluc Global warming potential - land use and land use change0,00203kg CO2 eq./kg
GWP-total Global warming potential - total2,97kg CO2 eq./kg
ODP Depletion potential of the stratospheric ozone layer0kg CFC-11 eq./kg
AP Acidifcation potential - Accumulated Exceedance0,00452mol H+ eq./kg
EP-freshwater Eutrophication potential - freshwater0,00121kg P eq./kg
EP-marine Eutrophication potential - marine0,00121kg N eq./kg
EP-terrestrial Eutrophication potential - terrestrial0,0131mol N eq./kg
POCP Photochemical Ozone Creation Potential0,00954kg NMVOC eq./kg
Indicators describing resource use
PERE Primary energy renewable - energy resources6,49MJ/kg
PERM Primary energy renewable - material0MJ/kg
PERT Primary energy renewable - total6,49MJ/kg
PENRE Primary energy non-renewable - energy resources43,4MJ/kg
PENRM Primary energy non-renewable - material40,6MJ/kg
PENRT Primary energy non-renewable - total84,0MJ/kg
Core environmental impact indicators
ADPE Abiotic depletion potential - non-fossil resources0,000000531kg Sb eq./kg
ADPF Abiotic depletion potential - fossil resources88,0MJ/kg
WDP Water (user) deprivation potential0,229m³ world eq. deprived/kg
Indicators describing resource use
SM Use of secondary material0kg/kg
RSF Use of renewable secondary fuels0MJ/kg
NRSF Use of non renewable secondary fuels0MJ/kg
FW Use of net fresh water0,0134m³/kg
Environmental information describing waste categories
HWD Hazardous waste disposed0,0000000091kg/kg
NHWD Non hazardous waste dispose0,0241kg/kg
RWD Radioactive waste disposed0,000815kg/kg
Environmental information describing output flows
CRU Components for re-use0kg/kg
MFR Materials for recycling0kg/kg
MER Materials for energy recovery0kg/kg
EEE Exported electrical energy0MJ/kg
EET Exported thermal energy0MJ/kg
Beschreibung des Richtwerts
Quelle: ONORM 8110-7 Wärmeschutz im Hochbau - Teil 7: Tabellierte wärmeschutztechnische Bemessungswerte

Tabelle 32 - Extrudierter Polystyrol-Hartschaum (XPS) gemäß ÖNORM EN 13164 und ÖNORM B 6000 - Zeile: 5

 

Verwendungsart laut ÖNORM B 6000:

XPS-G -Platte mit glatter Oberfläche, feuchtigkeitsbelastbar, zur Wärmedämmung von Wänden, Decken und Dächern; auch für Konstruktionen mit erhöhter und hoher Druckbelastbarkeit (zB Parkdecks für LKWs, Feuerwehr-Fahrzeuge) und Perimeterdämmung

 
Produkte mit diesem Richtwert
5 Produkte Hersteller
AUSTROTHERM XPS TOP 30 SFAUSTROTHERM
AUSTROTHERM XPS TOP 30 TBAUSTROTHERM
JACKODUR EVOJACKON Insulation GmbH
JACKODUR KF 300JACKON Insulation GmbH
Styrodur 3000CSBASF SE
baubook green procurement